Tag Archives: DWDM wavelength

The Art of DWDM Wavelength-Case Study of DWDM Networking

DWDM network is widely accepted as the best solution to increase network capacity over long distances. Making full use of these DWDM wavelengths for transmission needs to consider both now and future. This makes the design of the DWDM network complex. Here shares a true case of DWDM networking, which fulfills the requirement for now, but is also built for the future.DWDM networking

DWDM Networking Requirement

Three duplex DWDM links (Link A, Link B and Link C) should be built between three different sites: Site 1, Site 2 and Site 3. The following table listed the distance and light loss of these three links.

Duplex DWDM Links Distance Light Loss
Link A: Site 1 – Site 2 31km 9dB
Link B: Site 2 – Site 3 31km 9dB
Link C: Site 1 – Site 3 59km 17dB

A backup link of Link C should be built as well. This backup link will use as length of dark fiber which passes Site 4. Thus, another two links—Link D and Link E work together as the backup for Link C. Meanwhile, Link D and Link E also work independently for 6 ways of optical transmission. The following table lists the distance and the light loss of these links.

Duplex DWDM Links Distance Light Loss
Link D 24km 7dB
Link E 47km 13dB
Backup Link C (Link D+E) 71km (24km+47km) 20dB (7dB+13dB)
DWDM Networking Solution

As not all the links in this DWDM network are transmitting the same information, different wavelengths should be used. For instance, Link A and Link B only transmit 2 ways of optical signal, while Link C is required to transmit 10 ways of optical signal. And some of them are of different data rates. Assignment of the DWDM wavelengths in these links is very important. Considering the future network expanding needs, Site 1, Site 2 and Site 3 are suggested to deploy 40-Channel DWDM MUX/DEMUXs. The following will offer a detailed solution for each link.2 Channel DWDM network

Link A: 2*10G Over 31km

Link A is from Site 1 to Site 2, which is 31 kilometers long with light loss of 9dB. It only needs to transmit two ways 10G optical signal. In this link, we use DWDM wavelength, C21 and C50 for transmission. DWDM SFP+ modules that support 80km is used. In this link, no other devices are required to booster the optical signals, as the light source from the 80km modules are powerful enough to support this link. The required products on Site 1 and Site 2 are listed in the following table:

Location Product Parameter
Site 1 DWDM MUX/DEMUX 40-Channel
10G 80km DWDM SFP+ C21,C50
Site 2 DWDM MUX/DEMUX 40-Channel
10G 80km DWDM SFP+ C21,C50

2 Channel DWDM network

Link B: 2*10G Over 31km

Link B is from Site 2 to Site 3. Just like Link A, it required to support two ways of 10G transmission over distance of 31km. For Link B, we use the same products as for Link A.

Location Product Parameter
Site 2 DWDM MUX/DEMUX 40-Channel
10G 80km DWDM SFP+ C21,C50
Site 3 DWDM MUX/DEMUX 40-Channel
10G 80km DWDM SFP+ C21,C50
Link C: 2*1G & 8*10G Over 57km

Link C is from Site 1 to Site 3. It is required to transmit 2 ways of 1G optical signal and 8 ways of 10G optical signal at the same time over a distance of 57km with light loss of 17dB. Compared with Link A and Link B, things are much different for Link C, as the distance, network capacity and power consumption are all increased. It means more devices should be added.dwdm link toplogy link c

Overcome Large Light Loss: To ensure that the optical signals are powerful enough to reach the distance, EDFA are suggested to be deployed. An 13dB output booster EDFA is suggested to be deployed after the DWDM MUX Tx end in both Site 1 and Site 3.

Overcome High Power Consumption: As the more wavelengths are used in Link C, more DWDM fiber optic modules should be used. As the power consumption of DWDM modules are higher than normal optical modules, install large sum of DWDM modules in one switch would increase the risk of fault caused by high power consumption. OEO converter which can support the optical wavelengths transmission between normal SMF & MMF wavelengths to DWDM wavelengths are suggested to be deployed between DWDM MUX/DEMUX and switch. This can reduce the fault risk caused by high power consumption effectively.

The product required for Link C are listed as following:

Location Product Parameter
Site 1 DWDM MUX/DEMUX 40-Channel
2*1G 80km DWDM SFP C23, C48
8*10G 80km DWDM SFP+ C21, C22, C30, C31, C49, C50, C59, C60
2*OEO 8-port
EDFA (OPA) 13dB
Site 3 DWDM MUX/DEMUX 40-Channel
2*1G 80km DWDM SFP C23, C48
8*10G 80km DWDM SFP+ C21, C22, C30, C31, C49, C50, C59, C60
2*OEO 8-port
EDFA (OPA) 13dB
Backup Link C = Link D + Link E

Link D and link E are working together as the backup Link C, so ten different wavelengths should be used as in Link C. Meanwhile, both Link D and Link E are working independently. Both of them are transmitting 6 ways of optical signal. Here we used two OAMDs at Site 4 to multiplex another 6 wavelengths into the existing network. Link D + Link E is 71 kilometers long, which is much longer than Link C. To support this backup link, except the devices used in Link C, 20dB optical booster EDFA is suggested to be added in both Site 1 and Site 3 at the DWDM Mux/DEMUX RX port.backup DWDM link

As Link D is only 24km and link E is 47km, for their independent working, DWDM SFP+ modules support 40km is suggested. The following listed the products for Link D + Link E in Site 1, Site3 and Site 4.

Location Product Parameter Function
Site 1 DWDM MUX/DEMUX 40-Channel Backup of Link C
2*1G 80km DWDM SFP C23, C48
8*10G 80km DWDM SFP+ C21, C22, C30, C31, C49, C50, C59, C60
2*OEO 8-port
EDFA (OPA) 13dB
EDFA (OBA) 20dB
6*10G 40km DWDM SFP+ C53, C54, C55, C56, C57, C58 Link D Works independently
Site 4 6*10G 40km DWDM SFP+ C53, C54, C55, C56, C57, C58
OADM 6-Channel: C53, C54, C55, C56, C57, C58
OADM 6-Channel: C53, C54, C55, C56, C57, C58 Link E Works independently
6*10G 80km DWDM SFP+ C53, C54, C55, C56, C57, C58
Site 3 6*10G 80km DWDM SFP+ C53, C54, C55, C56, C57, C58
DWDM MUX/DEMUX 40-Channel Backup of Link C
2*1G 80km DWDM SFP C23, C48
8*10G 80km DWDM SFP+ C21, C22, C30, C31, C49, C50, C59, C60
2*OEO 8-port
EDFA (OPA) 13dB
EDFA (OBA) 20dB
Products in this DWDM Networking Case

The products mentioned in the above case are all provided by FS.COM. Here offer the details for your reference. In FS.COM, you can offer your requirement for networking to the tech support team and get suitable and reliable performance solutions for your projects.

DWDM MUX/DEMUX 40-CH DWDM MUX/DEMUX
DWDM OADM 6-CH DWDM OADM
DWDM SFP 80km DWDM SFP
DWDM SFP+ 80km DWDM SFP+
40km DWDM SFP+
EDFA 13dB EDFA (OPA)
20dB EDFA (OBA)
Transponder (OEO) 8-Port 3R OEO Converter